Results Detail | PFOA | GAC Reactivation | Lab | Treatment Media | 1000 °C | 10 minute | ≈78% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 2 |
Results Detail | PFOA | GAC Reactivation | Lab | Treatment Media | 1000 °C | 10 minute | ≈1% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 2 |
Results Detail | PFOA | GAC Reactivation | Lab | Treatment Media | 700 °C | 10 minute | ≈27% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F |
Results Detail | PFOA | GAC Reactivation | Lab | Treatment Media | 700 °C | 10 minute | ≈5% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F |
Results Detail | PFOA | GAC Reactivation | Lab | Treatment Media | 700 °C | 10 minute | ≈15% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F |
Results Detail | PFOA | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈10% | 10 mg/g | Not detected | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 2 |
Results Detail | PFOA | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈2% | 10 mg/g | Not detected | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 2 |
Results Detail | PFOA | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈45% | 10 mg/g | Not detected | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 2 |
Results Detail | PFOA | GAC Reactivation | Lab | Treatment Media | 900 °C | 10 minute | ≈8% | 10 mg/g | Not detected | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 2 |
Results Detail | PFOA | GAC Reactivation | Lab | Treatment Media | 900 °C | 10 minute | ≈53% | 10 mg/g | Not detected | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 2 |
Results Detail | PFBA | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈0.026% | 0 mg/g | | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFBA | GAC Reactivation | Lab | Treatment Media | 900 °C | 10 minute | ≈0.17% | 0 mg/g | | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFBA | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈0.029% | 0 mg/g | | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 2 |
Results Detail | PFBA | GAC Reactivation | Lab | Treatment Media | 900 °C | 10 minute | ≈0.03% | 0 mg/g | | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 2 |
Results Detail | PFHxA | GAC Reactivation | Lab | Treatment Media | 1000 °C | 10 minute | ≈1% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFHxA | GAC Reactivation | Lab | Treatment Media | 1000 °C | 10 minute | ≈80% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFHxA | GAC Reactivation | Lab | Treatment Media | 1000 °C | 10 minute | ≈1% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFHxA | GAC Reactivation | Lab | Treatment Media | 700 °C | 10 minute | ≈5% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFHxA | GAC Reactivation | Lab | Treatment Media | 700 °C | 10 minute | ≈8% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFHxA | GAC Reactivation | Lab | Treatment Media | 700 °C | 10 minute | ≈42% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFHxA | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈77% | 10 mg/g | Not detected | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFHxA | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈4% | 10 mg/g | Not detected | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFHxA | GAC Reactivation | Lab | Treatment Media | 900 °C | 10 minute | ≈64% | 10 mg/g | Not detected | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFHxA | GAC Reactivation | Lab | Treatment Media | 900 °C | 10 minute | ≈7% | 10 mg/g | Not detected | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 1000 °C | 10 minute | ≈1% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 1000 °C | 10 minute | ≈80% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 700 °C | 10 minute | ≈8% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 700 °C | 10 minute | ≈2% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 700 °C | 10 minute | ≈76% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈3% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈75% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈4% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 900 °C | 10 minute | ≈3% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 900 °C | 10 minute | ≈2% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFOS | GAC Reactivation | Lab | Treatment Media | 900 °C | 10 minute | ≈82% | 10 mg/g | Not detected | Not detected | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 4 |
Results Detail | PFPeA | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈0.017% | 0 mg/g | | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 3 |
Results Detail | PFPeA | GAC Reactivation | Lab | Treatment Media | 800 °C | 10 minute | ≈0.02% | 0 mg/g | | | No PFASs remained in either quartz tube or GAC; quantification limit = 0.05 ug F; No VOF recovered in Tenax TA tube; quantification limit = 0.3 ug F; data interpolated from Fig. 2 |