Skip to Main Content

Reference Details

Citation
Yamada et al 2005
Author
Yamada, T., Taylor, P.H., Buck, R.C., Kaiser, M.A., and Giraud, R.J.
Title
Thermal degradation of fluorotelomer treated articles and related materials
Source
Chemosphere
Publication Year
2005
Reference Category
Primary Sources
Reference Type
Peer Reviewed Journals
Source Details
DOI: 10.1016/j.chemosphere.2005.03.025
DOI
10.1016/j.chemosphere.2005.03.025Exit
Non-Targeted Analysis Flag
Yes
Non-Targeted Analysis Details
GC/MS peak analysis indicated ions (•CF3: 69, •CF2CH@CH2: 77) are plausible fluorotelomer-based acrylic polymer combustion byproducts. (pgs. 979-980)

Scope

Open ScopeMatrix DetailScope Detail
Open ScopeIncinerationLabOtherFabric; an untreated article, and a fluorotelomer-based acrylic polymer treated article.Identification (none detected) of combustion byproducts in off gas, including PFOA. Also includes non-targeted GC/MS analysis of off-gas byproducts, not captured in data entry.

Condition

Open ConditionIncineration | Lab | Other: Fabric; an untreated article, and a fluorotelomer-based acrylic polymer treated article.2 secondThermal experiments were conducted at non-flame reactor temperatures from 600 to 1000C for a mean, gas-phase residence time of 2.0 s. 85% excess air was used for all ATRS experiments.

Thermal Treatment Results