Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Other | 260 °C | 60 minute | 0% | | | | Results interpreted from Figure 2 |
Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Other | 260 °C | 60 minute | 25% | | | | Results interpreted from Figure 2 |
Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Other | 300 °C | 60 minute | 20% | | | | Results interpreted from Figure 2 |
Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Other | 300 °C | 60 minute | 95% | | | | Results interpreted from Figure 2 |
Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Other | 350 °C | 60 minute | 98% | | | | Results interpreted from Figure 2 |
Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Other | 350 °C | 60 minute | 40% | | | | Results interpreted from Figure 2 |
Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Sludge | 260 °C | 60 minute | 0% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 2 |
Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Sludge | 300 °C | 60 minute | 0% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 2 |
Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Sludge | 350 °C | 30 minute | 30% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Sludge | 350 °C | 60 minute | 93% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | 7:3 FTCA | Hydrothermal Treatment | Lab | Sludge | 350 °C | 90 minute | >99% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Other | 260 °C | 60 minute | 17% | | | | Results interpreted from Figure 2 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Other | 260 °C | 60 minute | >99% | | | | Results interpreted from Figure 2 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Other | 300 °C | 60 minute | 42% | | | | Results interpreted from Figure 2 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Other | 300 °C | 60 minute | >99% | | | | Results interpreted from Figure 2 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Other | 350 °C | 60 minute | 48% | | | | Results interpreted from Figure 2 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Other | 350 °C | 60 minute | >99% | | | | Results interpreted from Figure 2 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Sludge | 260 °C | 60 minute | >99% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 2 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Sludge | 300 °C | 60 minute | >99% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 2 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Sludge | 350 °C | 30 minute | >99% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Sludge | 350 °C | 60 minute | >99% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | 8:2 FTUCA | Hydrothermal Treatment | Lab | Sludge | 350 °C | 90 minute | >99% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Other | 260 °C | 60 minute | 17% | | | | Results interpreted from Figure 2 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Other | 260 °C | 60 minute | 38% | | | | Results interpreted from Figure 2 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Other | 300 °C | 60 minute | 20% | | | | Results interpreted from Figure 2 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Other | 300 °C | 60 minute | 25% | | | | Results interpreted from Figure 2 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Other | 350 °C | 60 minute | 10% | | | | Results interpreted from Figure 2 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Other | 350 °C | 60 minute | 61% | | | | Results interpreted from Figure 2 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Sludge | 260 °C | 60 minute | 26% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 2 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Sludge | 300 °C | 60 minute | 49% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 2 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Sludge | 350 °C | 30 minute | 50% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Sludge | 350 °C | 60 minute | 52% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | FtS 8:2 | Hydrothermal Treatment | Lab | Sludge | 350 °C | 90 minute | 66% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Other | 260 °C | 60 minute | >99% | | | | Results interpreted from Figure 2 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Other | 260 °C | 60 minute | 18% | | | | Results interpreted from Figure 2 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Other | 300 °C | 60 minute | >99% | | | | Results interpreted from Figure 2 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Other | 300 °C | 60 minute | 30% | | | | Results interpreted from Figure 2 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Other | 350 °C | 60 minute | >99% | | | | Results interpreted from Figure 2 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Other | 350 °C | 60 minute | 13% | | | | Results interpreted from Figure 2 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Sludge | 260 °C | 60 minute | >99% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 2 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Sludge | 300 °C | 60 minute | >99% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 2 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Sludge | 350 °C | 30 minute | 98% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Sludge | 350 °C | 60 minute | >99% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | PFOA | Hydrothermal Treatment | Lab | Sludge | 350 °C | 90 minute | >99% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Other | 260 °C | 60 minute | 0% | | | | Results interpreted from Figure 2 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Other | 260 °C | 60 minute | 0% | | | | Results interpreted from Figure 2 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Other | 300 °C | 60 minute | 0% | | | | Results interpreted from Figure 2 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Other | 300 °C | 60 minute | 0% | | | | Results interpreted from Figure 2 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Other | 350 °C | 60 minute | 0% | | | | Results interpreted from Figure 2 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Other | 350 °C | 60 minute | 0% | | | | Results interpreted from Figure 2 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Sludge | 260 °C | 60 minute | 39% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 2 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Sludge | 300 °C | 60 minute | 35% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 2 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Sludge | 350 °C | 30 minute | 7% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Sludge | 350 °C | 60 minute | 46% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |
Results Detail | PFOS | Hydrothermal Treatment | Lab | Sludge | 350 °C | 90 minute | 33% | 1000 ng/g | | | Nanograms contaminant per gram of solids sludge; results interpreted from Figure 3 |