Results Detail | N-Me-FOSE alcohol | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | N-Me-FOSE alcohol | Incineration | Pilot | Other | 870 °C | 4 second | | | | ND | Data from Table 3, setting S1; data include five samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFOA | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFOA | Incineration | Pilot | Other | 870 °C | 4 second | | | | | Data from Table 3, setting S1; data include five samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ |
Results Detail | PFBS | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | 141 ng/dscm | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFBS | Incineration | Pilot | Other | 870 °C | 4 second | | | | ND | Data from Table 3, setting S1; data include five samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ |
Results Detail | PFDA | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFDA | Incineration | Pilot | Other | 870 °C | 4 second | | | | 128 ng/dscm | Data from Table 3, setting S1; data include five samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ |
Results Detail | PFDoA | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | ND | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFDoA | Incineration | Pilot | Other | 870 °C | 4 second | | | | 124 ng/dscm | Data from Table 3, setting S1; data include five samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ |
Results Detail | PFHpA | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | 135 ng/dscm | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFHpA | Incineration | Pilot | Other | 870 °C | 4 second | | | | 156 ng/dscm | Data from Table 3, setting S1; data include five samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ |
Results Detail | PFHxA | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | 136 ng/dscm | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFHxA | Incineration | Pilot | Other | 870 °C | 4 second | | | | ND | Data from Table 3, setting S1; data include five samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ |
Results Detail | PFNA | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | ND | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFNA | Incineration | Pilot | Other | 870 °C | 4 second | | | | ND | Data from Table 3, setting S1; data include five samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ |
Results Detail | PFTeDA | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | ND | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFTeDA | Incineration | Pilot | Other | 870 °C | 4 second | | | | 102 ng/dscm | Data from Table 3, setting S1; data include five samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ |
Results Detail | PFTriA | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | 134 ng/dscm | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFUnA | Incineration | Pilot | Other | 1020 °C | 2.7 second | | | | 133 ng/dscm | Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ |
Results Detail | PFUnA | Incineration | Pilot | Other | 870 °C | 4 second | | | | ND | Data from Table 3, setting S1; data include five samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ |