Reference
Sasi, P.C., Alinezhad, A., Yao, B., Kubátová, A., Golovko, S.A., Golovko, M.Y., and Xiao, F. (2021) Effect of granular activated carbon and other porous materials on thermal decomposition of per- and polyfluoroalkyl substances: Mechanisms and implications for water purification - Water Research
Treatment Process
Indirect Thermal Desorption
Test Scale
Lab
Matrix
Other
Matrix Detail
Pure PFAS
Data Detail
Data in the study are not presented in a format readily recorded in the database. Conclusions include that "...the thermolysis of perfluoroalkyl carboxylic acids (PFCAs), including perfluorooctanoic acid (PFOA), and GenX can occur at temperatures of 150–200 degrees C."

Condition

No data found.

Thermal Treatment Results