Skip to Main Content

Condition Details

Reference
Arkenbout, A. (2018) Long-term sampling emission of PFOS and PFOA of a Waste-to-Energy incinerator - NGO ToxicoWatch
Scope
Incineration | Full | Other: Unspecified waste
Treatment Temperature (°C)
850
Treatent Time
2
Time Units
Second
Treatment Details
Regulatory minimum for waste incineration processing in the study locale (Harlingen, The Netherlands). Not necessarily the conditions at which field measurements were made during the study period.

Thermal Treatment Results

PFOA≈18.6 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOS≈1.4 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOA≈13.5 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOS≈1.9 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOA≈11.8 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOS≈1.9 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOS≈1.1 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOA≈15.3 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOS≈8.1 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOA≈40.4 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOS≈1.7 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2
PFOA≈31.1 pg/Nm3 ESTIMATE: Values estimated from plot in Fig 2