Condition Details
- Reference
- Krug, J., Lemiux, P.M., Lee, C-W., Ryan, J.V., Kariher, P., Shields, E., Wickersham, L., Denison, M., Davis, K., Swensen, D., Burnette, R., Wendt, J.O.L., and Linak, W.P. (2021) Combustion of C1 and C2 PFAS: Kinetic Modeling and Experiments - 38th International Conference on Thermal Treatment Technologies and Hazardous Waste Combustors
- Scope
- Incineration | Pilot | Other: Pure PFAS
- Treatment Temperature (°C)
- 900
- Treatent Time
- 3.3
- Time Units
- Second
- Treatment Details
- Port 11. Temperature is modeled. PFAS introduced with the natural gas or combustion air (t=0 sec) experience the full temperature profile (Figure 3) and flame chemistry before being analyzed by FTIR at Port 18 (t~7.4 sec). However, PFAS introduced at Ports 4‐12 experienced reduced temperatures, residence times, and exposure to flame chemistry. For example, CHF3 introduced at Port 12, was exposed to peak temperatures of ~830 °C (1526 °F) before being analyzed by FTIR at Port 18 ~3 sec later.