Condition Details
- Reference
- Krug, J. D., Lemieux, P. M., Lee, C. W., Ryan, J. V., Kariher, P. H., Shields, E. P., ... and Linak, W. P. (2022) Combustion of C1 and C2 PFAS: Kinetic modeling and experiments - Journal of the Air & Waste Management Association
- Scope
- Incineration | Pilot | Other
- Treatment Temperature (°C)
- 1050
- Treatent Time
- 4.2
- Time Units
- Second
- Treatment Details
- Port 8; 45 kW loading experiment; The model assumes initial adiabatic flame temperature (2071 °C) and a linear temperature decay to Port 1. PFAS introduced with the natural gas or combustion air (t=0 sec) experience the full temperature profile (Figure 3) and flame chemistry before being analyzed by FTIR at Port 18 (t~7.4 sec). However, PFAS introduced at Ports 4‐12 experienced reduced temperatures, residence times, and exposure to flame chemistry.