Skip to Main Content

Condition Details

Reference
Krug, J. D., Lemieux, P. M., Lee, C. W., Ryan, J. V., Kariher, P. H., Shields, E. P., ... and Linak, W. P. (2022) Combustion of C1 and C2 PFAS: Kinetic modeling and experiments - Journal of the Air & Waste Management Association
Scope
Incineration | Pilot | Other
Treatment Temperature (°C)
1300
Treatent Time
5
Time Units
Second
Treatment Details
Port 4; 45 kW loading experiment; The model assumes initial adiabatic flame temperature (2071 °C) and a linear temperature decay to Port 1. PFAS introduced with the natural gas or combustion air (t=0 sec) experience the full temperature profile (Figure 3) and flame chemistry before being analyzed by FTIR at Port 18 (t~7.4 sec). However, PFAS introduced at Ports 4‐12 experienced reduced temperatures, residence times, and exposure to flame chemistry.