Skip to Main Content

Thermal Treatment Results

PFHxA136 ng/dscm Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ
PFHpA135 ng/dscm Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ
PFOA Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ
PFNAND Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ
PFDA Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ
PFUnA133 ng/dscm Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ
PFDoAND Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ
PFTriA134 ng/dscm Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ
PFTeDAND Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ
PFBS141 ng/dscm Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ
N-Me-FOSE alcohol Data from Table 3, setting S2; data include six samples, each the sum from four steps of the capture sampling train; in calculating sampling train totals, values less than LOQ were treated as 1/2 LOQ